Model 7000 Data Logger


Model 7000 Series
Water Monitoring Instruments

The Series 7000 data recording instruments are assembled from standard components to meet each customer's individual requirements.

An internal clock, re-settable by user, tags each data reading with the date and time at which it was taken.

The housing is our time-tested "hard coat anodized" aluminum cylinder with patented G.O. "spaghetti line" end cap locks. Housings are pressure rated to 5000 meters (sea water) when properly sealed.

The following chart helps illustrate the "Electronics" and "Environmental Sensors" which are available for each instrument. The specifications are the same for the various instruments listed.


    
    

Pressure Temp. Tilt Serial RS232 Mem Series Name Dir S Q Conductivity Ext Int. X Y Out Cable 128/512K ____________________________________________________________________________________________________ Model 7051 DepthGauge X * * * X * * Model 7051Q Tide Gauge Quartz X * * * * X * * Model 7011U Inclinometer X * * * X X * X * * Model 7070 Thermograph * * X * X * * ____________________________________________________________________________________________________ X = Standard factory item * = Optional item S = Strain gauge pressure sensor

Q = Quartz (high accuracy) crystal pressure sensor

Specifications

Time GMT:       Internal Quartz Crystal Clock, Accuracy +/- 1.0 sec/day. 
                                User settable.

Temperature:    Range: -5 C to +45 C
                Accuracy: +/- 0.25 C Resolution: .050 C
                Response Time: 30 seconds
                External Sensor: 2 seconds

Pressure:       Pressure Sensor Ranges:
                 0-15    PSI     34      feet    10      meters
                 0-30    PSI     67      feet    20      meters
                 0-100   PSI     224     feet    68      meters
                 0-500   PSI     1122    feet    341     meters  
                 0-2000  PSI     4487    feet    1368    meters
                 0-5000  PSI     11218   feet    3419    meters
                 0-10000 PSI     22436   feet    6838    meters
   Pressure housing is limited to 5000 Meters.
   Accuracy: 0.5% of range  Resolution: 0.1%
   Accuracy (Quartz Sensor) +/- .01%   Resolution (Quartz Sensor) +/- 0.005%
   Sampling Rates and Intervals are configured on screen with IBM/PC/AT.

Conductivity:   Toroid Inductive Coil encased in Teflon
                Accuracy: +/- 1.0mS/cm
                Range: 0 to 75 mS/cm
                Resolution: 0.10 mS/cm

Direction:      Magnetic Flux Gate
                    Accuracy +/- 2.0   Resolution: +/- 1.0  Range: 0 to 360 
                Tilt Sensor
                    Accuracy: +/- 0.1  Resolution: +/- 0.05 Range: 0 to 90 

Pressure Case:  (all instruments) 5,000 Meter (8,000 psi) anodized aluminum casing with                         o-ring end seals and the G.O. patented "spaghetti line" end cap locking                         systems.

Case Dimensions: Cylinder- 51.4 cm (20.25 in) x 10.5 cm diameter (4,125 in).

Instrument Weight: In Air- 6.9kg (15.17 lbs) maximum.